Hantek DSO 1062B (60 MHz) Digital Handheld Oscilloscope

Impressive design, intuitive control and high-resistance finish make oscilloscopes in the 1000B series useful aiders not only in field work, but also in hard industrial conditions. All Hantek oscilloscopes offer a great price/performance ratio at the low-end segment of measuring technology and the DSO 1062B is no exception. The advantages of Hantek Handheld over its rival products are the more than five times larger sampling memory, very good interference resistance, more accurate mulitmeter offering a larger number of ranges, a higher quality color display with a longer diagonal 5.6“ (14.5 cm), intuitive control and a long lasting battery (6 hours for a single recharge).

The device will meet the needs of measuring technology professionals, but also those of technical secondary school and college students as a multifunction aid for study. Its low price and quality technical design offer a high use value.

Its main features are the 60 MHz bandwidth and 1 GS/s (one-channel) maximum sampling rate. The other advantages of the Hantek DSO 1062B oscilloscope are its weight and compact size, which make it easily portable.

DSO 1062B - main features:

• Bandwidth: 60 MHz
• Rise Time: 5.8ns
• Sampling rate: 1 GS/s
• Record Length: 1M
• Zoom function
• Multimeter function
• 32 automatic measurements
• Measuring cursors
• Quick offset calibration
• Math functions including FFT
• Advanced trigger modes: Edge, Video, Pulse, Slope, Over time, Alternative
• Measurement record storage (supports bitmap and CSV format)
• Screen storage
• LabVIEW support
• Applications development support - Visual C, Visual Basic
• 5.6“ display with LED illumination; 640x480 point resolution
• USB Host: support removeable disk
• LAN: Optional
• Dimensions (mm): 240(L) x 165(W) x 50(H)

Multimeter parameters:

• Number of digits: 6000
• Measurement modes: U, I, R, f, diod test, continutity test
• Max. input voltage - AC: 600 V DC: 800 V
• Max. input current - AC: 10A DC: 10A
• True-RMS multimeter
• Input impedance: 10 M
• Isolated input: up to 1000 V
• Safety class: 1000 V CAT II and 600 V CAT III

Control Programme

The programme, which uses a pop-up menu, is user-friendly and easy to control. It is localized in English and includes a built-in help system. It features a whole range of standard functions frequently met with.

Favorable price - optimal performance

An obstacle for anyone interested in owning a good oscilloscope is the purchasing price of a digital oscilloscope. Quality oscilloscopes are expensive. Hantek brings an alternative and offers a balanced price/performance ratio. Measuring technology development and production are marching in seven-league boots, and everybody understands that computer technology prices have fallen sharply in the last decade. Measuring technology is no exception. Hantek offers a cheap and good quality solution, although not a perfect one. Hantek oscilloscopes are accessible to anyone interested in making the relevant measurements.

The DSO 1000B and 1000BV Oscilloscope Product Series

The DSO 1062B model is based on the Hantek 1000B Series. The Oscilloscopes from this series have common features: 2 channels, maximum sampling frequency 1GS/s, AC/DC/GND coupling, 3 % DC amplification accuracy, integrated multimeter, vertical resolution 8-bit. Product 1000BV Series compared to the series 1000B is extended only by 2G SD memory and preinstalled program module help videos. The most important technical parameters shall remain identical for oscilloscopes.

Package contents
Package includes:
1x Handheld DSO 1062B
2x Passive probe 60 MHz
1x Test probes for multimeter
1x Connecting cable 1,2m; USB 2.0
1x Power adapter
1x High quality nylon bag - Hantek
1x CD with software and Manual in English

DSO 1062B. CN

  • Price: €575 - In stock

Parameters

Warranty 2 years
Model 1062B
Parameters

Horizontal

Sample Rate Range 1GS/s
Waveform Interpolation (sin x)/x
Record Length Maximum 1Msamples per single-channel; maximum 512K  samples per dual-channel (4K,16K,40K optional)
TIME/DIV Range
4ns/div to 40s/div, in a  2, 4, 8 sequence
Sample Rate and
Delay Time Accuracy
±50ppm over any ≥1ms time interval
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode
± (1 sample interval +100ppm × reading + 0.6ns)
>16 averages
± (1 sample interval + 100ppm × reading + 0.4ns)
Sample interval = s/div ÷ 200
Position Range DSO1062B
4ns/div to 8ns/div
20ns/div to 80μs/div
200μs/div to 40s/div
2ns/div to 10ns/div
Vertical
A/D Converter 8-bit resolution, each channel sampled simultaneously
VOLTS Range 2mV/div to 5V/div at input BNC
Position Range 2mV/div to 200mV/div, ±2V
>200mV/div to 5V/div, ±50V
Analog Bandwidth in
Normal and Average
modes at BNC or with probe, DC Coupled
2mV/div to 20mV/div, ±400mV
50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V
5V/div, ±50V
Selectable Analog Bandwidth Limit, typical 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
Rise Time at BNC, typical
<5.8ns
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]
Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

 Note: Bandwidth reduced to 6MHz when using a 1X probe.

Trigger

Trigger Sensitivity
(Edge Trigger Type)
Coupling Sensitivity
DC Source
CH1
CH2
1div from DC to 10MHz;
1.5div from 10MHz to Full
AC Attenuates signals below 10Hz
HF Reject Attenuates signals above 80kHz
LF Reject Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range Source Range
CH1, CH2 ±8 divisions from center of screen
Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall times ≥20ns) Source Accuracy
CH1, CH2 0.2div × volts/div within ±4 divisions from center of screen
Set Level to 50%, typical Operates with input signals ≥50Hz

Note: Bandwidth reduced to 6MHz when using a 1X probe.

Video Trigger Type Source Range
CH1, CH2 Peak-to-peak amplitude of 2 divisions
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns to 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when < (Less than), > (Greater than), = (Equal), or ≠ (Not Equal); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Pulse Width Range Selectable from 20ns to 10s
Slope Trigger
Slope Trigger Mode Trigger when < (Less than), > (Greater than), = (Equal), or ≠ (Not Equal); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range Selectable from 20ns to 10s
Overtime Trigger The leading edge: Rising edge or Falling edge; Time Setting: 20-10s
Swap Trigger
CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Acquisition
Acquisition Modes Normal, Peak Detect, and Average
Acquisition Rate, typical Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement)
Single Sequence Acquisition Mode Acquisition Stop Time
Normal, Peak Detect Upon single acquisition on all channels
simultaneously
Average After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128

Inputs

Inputs
Input Coupling DC, AC or GND
Input Impedance, DC coupled 1MΩ±2% in parallel with 20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factors 1X, 10X, 100X, 1000X
Maximum Input Voltage Overvoltage Category Maximum Voltage
CAT I and CAT II 300VRMS (10×), Installation Category

CAT III

150VRMS (1×)

Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Measurements

Cursors

Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)

Automatic Measurements

Frequency, Period, Mean, Peak-to-peak, Cycle RMS, Minimum, Maximum, Rise Time, Fall Time, Positive Width, Negative Width

General Specifications

Display

Display Type

5.6 Inch width TFT Display

Display Resolution

480 (Vertical) X 640(Horizontal) pixels

Display Contrast

Adjustable (16 gears) with the progress bar

Probe Compensator Output

Output Voltage, typical

About 5Vpp into ≥1MΩ load

Frequency, typical

1kHz

Power Supply

Switching Adatper

AC Input:100-240VACRMS,0.6AMAX,50Hz-60Hz; DC Output:9V,2A

DC Input

DC8.5-15V,2A

Power Consumption

<30W

Environmental

Temperature

Operating:32℉to122℉(0℃to50℃)

Nonoperating:-40℉to159.8℉(-40℃to +71℃)

Cooling Method

Convection

Humidity

+104℉or below (+40℃or below): ≤90% relative humidity

106℉to122℉(+41℃to50℃): ≤60% relative humidity

Altitude

Operating and Nonoperating

3,000m(10,000 feet)

 

Random Vibration

0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis

 

Nonoperating

2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis

Mechanical Shock

Operating

50g, 11ms, half sine

Mechanical

Size

Length

245mm

Height

163mm

Depth

52mm

Weight

 

1.2 Kg

Meter Mode

Maximum Resolution

6000 Counts

DMM Testing Modes

Voltage,Current,Resistance,Capacitance,Diode & Continuity

Maximum Input Voltage

AC : 600V DC : 800V

Maximum Input Current

AC :10ADC :10A

Input Impedance

10MΩ

Meter Specification

Range

Accuracy

Resolution

DC Voltage

60.00mV(manual)

±1%±1digit

10uV

600.0mV

100uV

6.000V

1mV

60.00V

10mV

600.0V

100mV

800V

1V

AC Voltage

 

60.00mV(manual)

±1%±3digit

10uV

600.0mV(manual)

100uV

6.000V

1mV

60.00V

10mV

600.0V

100mV

DC Current

60.00mA

±1.5%±1digit

10uA

600.0mA

±1%±1digit

100uA

6.000A

±1.5%±3digit

1mA

10.00A

10mA

AC Current

60.00mA

±1.5%±3digit

10uA

600.0mA

±1%±1digit

100uA

6.000A

±1.5%±3digit

1mA

10.00A

10mA

Resistance

600.0

±1%±1digit

 

0.1Ω

6.000K

60.00K

10Ω

600.0K

100Ω

6.000M

1KΩ

60.00M

±1.5%±3digit

10KΩ

Capacitance

 

40.00nF

±1%±1digit

10pF

400.0nF

100pF

4.000uF

1nF

40.00uF

10nF

400.0uF

100nF

Attention:The smallest capacitance value that can be measured is 5nF.

Diode

0V~2.0V

On-off Test

< 30Ω

Demonstrations

Videos No
Pictures No

Support

Manual No
Datasheet No
Software No
FAQ No

Reviews

You're reviewing: DSO 1062B

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Price
Value

You may also like

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

New handhelds